25.04.12
GWM 50/7600 A
This sensor uses the physical principle of magnetostriction with high-precision, reproducible contactless position measurement. The key component of the displacement transducer is the ferromagnetic measuring element – the waveguide. The movable position magnet generates a longitudinal magnetic fi eld in the waveguide. When a current pulse passes through the wave-guide, a
second magnetic fi eld is created radially around the waveguide. The convergence of the two magnetic fi elds produces a strain pulse that travels at a constant ultrasonic speed in the form of an acoustic wave from its point of origin – the measurement point – to the ends of the waveguide. It is transformed in the sensor element into an electric pulse that is processed by the evaluation
electronics and turned into an analogue signal for automatic recording.
More informations: Transducer > Displacement and strain >